-- CISCO-SYSLOG-MIB.my: Cisco syslog message MIB file
--
-- August 1995, Scott Mordock
--
-- Copyright (c) 1995-1997, 2005 by cisco Systems, Inc.
-- All rights reserved.
-- *****************************************************************
---- This MIB provides a means to gather syslog messages generated
-- by the Cisco IOS-- Terminology:
-- Various textual messages are generated by the Cisco IOS. The IOS
-- can be configured such that these messages are sent to a "syslog"
-- server. With this MIB these same messages can also be received via
-- the SNMP. These messages are hereupon referred to as "syslog
-- messages" in this document. Note: Messages generated as a result
-- of entering CLI debug commands are not made available via the SNMP
-- at this time.
--
-- All IOS syslog messages have the following attributes:
-- timestamp (optional), facility name (where the message came
-- from), severity, message name, message text
--
-- The following example is often seen:
-- %SYS-5-CONFIG_I: Configured from console ...
-- where facility=SYS, severity=5, message name=CONFIG_ICISCO-SYSLOG-MIB DEFINITIONS::=BEGINIMPORTSMODULE-IDENTITY,NOTIFICATION-TYPE,OBJECT-TYPE,Integer32,Counter32,Unsigned32FROM SNMPv2-SMI
TEXTUAL-CONVENTION,DisplayString,TimeStamp,TruthValue,RowStatusFROM SNMPv2-TC
MODULE-COMPLIANCE,OBJECT-GROUP,NOTIFICATION-GROUPFROM SNMPv2-CONF
SnmpAdminStringFROM SNMP-FRAMEWORK-MIB
ciscoMgmt
FROM CISCO-SMI
InetAddress,InetAddressTypeFROM INET-ADDRESS-MIB;ciscoSyslogMIB MODULE-IDENTITYLAST-UPDATED"200512030000Z"ORGANIZATION"Cisco Systems, Inc."CONTACT-INFO" Cisco Systems
Customer Service
Postal: 170 W Tasman Drive
San Jose, CA 95134
USA
Tel: +1 800 553-NETS
E-mail: cs-snmp@cisco.com"DESCRIPTION"The MIB module to describe and store the system
messages generated by the IOS and any other
OS which supports syslogs."REVISION"200512030000Z"DESCRIPTION"Removed UNITS clause for clogOriginIDType
as UNITS clause is not applicable."REVISION"200508110000Z"DESCRIPTION"Added following objects:
clogOriginIDType
clogOriginID"REVISION"200506010000Z"
DESCRIPTION"Added clogServerGroup."REVISION"9508070000Z"DESCRIPTION"Initial version of this MIB module."::={ ciscoMgmt 41}ciscoSyslogMIBObjects OBJECTIDENTIFIER::={ ciscoSyslogMIB 1}-- SubgroupsclogBasic OBJECTIDENTIFIER::={ ciscoSyslogMIBObjects 1}clogHistory OBJECTIDENTIFIER::={ ciscoSyslogMIBObjects 2}
clogServer OBJECTIDENTIFIER::={ ciscoSyslogMIBObjects 3}-- Textual ConventionsSyslogSeverity ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"The severity of a syslog message. The enumeration
values are equal to the values that syslog uses + 1.
For example, with syslog, emergency=0.
'emergency' : system is unusable
'alert' : action must be taken immediately
'critical' : critical conditions
'error' : error conditions
'warning' : warning conditions
'notice' : normal but significant condition
'informational': informational messages
'debug' : debug-level messages."REFERENCE"RFC 3164, Section 4.1 - syslog Message Parts"SYNTAXINTEGER{ emergency(1),alert(2),critical(3),error(4),warning(5),
notice(6),info(7),debug(8)}-- Basic syslog objectsclogNotificationsSent OBJECT-TYPESYNTAXCounter32UNITS"notifications"MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of clogMessageGenerated notifications that
have been sent. This number may include notifications
that were prevented from being transmitted due to
reasons such as resource limitations and/or
non-connectivity. If one is receiving notifications,
one can periodically poll this object to determine if
any notifications were missed. If so, a poll of the
clogHistoryTable might be appropriate."::={ clogBasic 1}clogNotificationsEnabled OBJECT-TYPESYNTAXTruthValueMAX-ACCESSread-writeSTATUScurrentDESCRIPTION"Indicates whether clogMessageGenerated notifications
will or will not be sent when a syslog message is
generated by the device. Disabling notifications
does not prevent syslog messages from being added
to the clogHistoryTable."DEFVAL{ false }::={ clogBasic 2}clogMaxSeverity OBJECT-TYPESYNTAX SyslogSeverity
MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"Indicates which syslog severity levels will be
processed. Any syslog message with a severity value
greater than this value will be ignored by the agent.
note: severity numeric values increase as their
severity decreases, e.g. 'error' is more severe than
'debug'."DEFVAL{ warning }::={ clogBasic 3}clogMsgIgnores OBJECT-TYPESYNTAXCounter32UNITS"messages"MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of syslog messages which were ignored. A
message will be ignored if it has a severity value
greater than clogMaxSeverity."::={ clogBasic 4}clogMsgDrops OBJECT-TYPE
SYNTAXCounter32UNITS"messages"MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of syslog messages which could not be
processed due to lack of system resources. Most
likely this will occur at the same time that syslog
messages are generated to indicate this lack of
resources. Increases in this object's value may serve
as an indication that system resource levels should be
examined via other mib objects. A message that is
dropped will not appear in the history table and
no notification will be sent for this message."::={ clogBasic 5}
clogOriginIDType OBJECT-TYPESYNTAXINTEGER{none (1),other (2),hostName (3),ipv4Address (4),contextName (5),userDefined (6)}
MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"This object identifies the type of value that
will be contained in clogOriginID object.
The possible value(s) are:
'none' : do not send origin identifier in
syslog messages.
'other' : type that is not identified by other
values specified in this object.
'hostName' : Send hostname of the system in syslog
messages.
'ipv4Address': Send IP address of the sending interface.
'contextName': Send context name of the security device.
'userDefined': Send user configured string in
syslog message.
The value 'other' and 'none' can not be set but
can only be read."DEFVAL{ none }::={ clogBasic 6}clogOriginID OBJECT-TYPESYNTAXSnmpAdminStringMAX-ACCESSread-writeSTATUScurrentDESCRIPTION"This object is used for configuring the
origin identifier for the syslog messages.
The origin identifier is useful for identifying
the source of system logging messages in cases
syslog messages from multiple devices are sent
to a single syslog host.
The origin identifier is added to the beginning of
all system logging (syslog) messages sent to remote
hosts.
The type of the identifier is specified
by clogOriginIDType object.
This object can be written by the SNMP manager
only when clogOriginIDType is set to 'userDefined'.
For following value(s) of clogOriginIDType,
this object can not be set; the value of this
object is derived by the system in these cases:
'contextName'
'ipv4Address'
'hostName'
'other'
'none'
This object contains the context name
of the device, when clogOriginIDType is
set to 'contextName'.
This object contains IPv4 address
(in dotted decimal notation) of the sending
interface when clogOriginIDType is set to
'ipv4Address'.
This object contains hostname of the system
when clogOriginIDType is set to 'hostName'.
This object will contain zero length
octet string when clogOriginIDType is
either 'none' or 'other'."DEFVAL{""}::={ clogBasic 7}-- Syslog message history tableclogHistTableMaxLength OBJECT-TYPESYNTAXInteger32(0..500)UNITS"entries"MAX-ACCESSread-writeSTATUScurrent
DESCRIPTION"The upper limit on the number of entries that the
clogHistoryTable may contain. A value of 0 will
prevent any history from being retained. When this
table is full, the oldest entry will be deleted and
a new one will be created."DEFVAL{1}::={ clogHistory 1}clogHistMsgsFlushed OBJECT-TYPESYNTAXCounter32UNITS"messages"MAX-ACCESSread-onlySTATUScurrentDESCRIPTION
"The number of entries that have been removed from
the clogHistoryTable in order to make room for new
entries. This object can be utilized to determine
whether your polling frequency on the history table
is fast enough and/or the size of your history table
is large enough such that you are not missing
messages."::={ clogHistory 2}clogHistoryTable OBJECT-TYPESYNTAXSEQUENCEOF ClogHistoryEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table of syslog messages generated by this device.
All 'interesting' syslog messages (i.e. severity <=
clogMaxSeverity) are entered into this table."::={ clogHistory 3}clogHistoryEntry OBJECT-TYPESYNTAX ClogHistoryEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A syslog message that was previously generated by this
device. Each entry is indexed by a message index."INDEX{ clogHistIndex }::={ clogHistoryTable 1}
ClogHistoryEntry ::=SEQUENCE{
clogHistIndex Integer32,
clogHistFacility DisplayString,
clogHistSeverity SyslogSeverity,
clogHistMsgName DisplayString,
clogHistMsgText DisplayString,
clogHistTimestamp TimeStamp}clogHistIndex OBJECT-TYPESYNTAXInteger32(1..2147483647)MAX-ACCESSnot-accessibleSTATUScurrent
DESCRIPTION"A monotonically increasing integer for the sole
purpose of indexing messages. When it reaches the
maximum value the agent flushes the table and wraps
the value back to 1."::={ clogHistoryEntry 1}clogHistFacility OBJECT-TYPESYNTAXDisplayString(SIZE(1..20))MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Name of the facility that generated this message.
For example: 'SYS'."::={ clogHistoryEntry 2}clogHistSeverity OBJECT-TYPESYNTAX SyslogSeverity
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The severity of the message."::={ clogHistoryEntry 3}clogHistMsgName OBJECT-TYPESYNTAXDisplayString(SIZE(1..30))MAX-ACCESSread-only
STATUScurrentDESCRIPTION"A textual identification for the message type.
A facility name in conjunction with a message name
uniquely identifies a message type."::={ clogHistoryEntry 4}clogHistMsgText OBJECT-TYPESYNTAXDisplayString(SIZE(1..255))MAX-ACCESSread-onlySTATUScurrentDESCRIPTION
"The text of the message. If the text of the message
exceeds 255 bytes, the message will be truncated to
254 bytes and a '*' character will be appended -
indicating that the message has been truncated."::={ clogHistoryEntry 5}clogHistTimestamp OBJECT-TYPESYNTAXTimeStampMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The value of sysUpTime when this message was
generated."::={ clogHistoryEntry 6}clogMaxServers OBJECT-TYPESYNTAXUnsigned32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The maximum number of syslog servers that can be
configured for the system in clogServerConfigTable.
A value of zero for this object indicates there is
no specified limit for the system and is only dictated
by system resources."::={ clogServer 1}clogServerConfigTable OBJECT-TYPESYNTAXSEQUENCEOF ClogServerConfigEntry
MAX-ACCESSnot-accessible
STATUScurrentDESCRIPTION"This table contains entries that allow application
to configure syslog servers for the system.
The maximum number of entries that can be created
for this table is limited by the object
clogMaxServers."::={ clogServer 2}clogServerConfigEntry OBJECT-TYPESYNTAX ClogServerConfigEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry containing information about syslog servers
configured for the system."
INDEX{ clogServerAddrType,
clogServerAddr }::={ clogServerConfigTable 1}
ClogServerConfigEntry ::=SEQUENCE{
clogServerAddrType InetAddressType,
clogServerAddr InetAddress,
clogServerStatus RowStatus}clogServerAddrType OBJECT-TYPESYNTAXInetAddressTypeMAX-ACCESSnot-accessibleSTATUScurrent
DESCRIPTION"The type of Internet address of this syslog server."::={ clogServerConfigEntry 1}clogServerAddr OBJECT-TYPESYNTAXInetAddress(SIZE(0..64))MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The Internet address of this syslog server.
The type of this address is determined by the
value of the clogServerAddrType object."
::={ clogServerConfigEntry 2}clogServerStatus OBJECT-TYPESYNTAXRowStatusMAX-ACCESSread-createSTATUScurrentDESCRIPTION"The status object used to manage rows in this table.
A row may only be created by setting this object to
'createAndGo'.
A row may only be deleted by setting this object to
'destroy'."::={ clogServerConfigEntry 3}-- notificationsciscoSyslogMIBNotificationPrefix OBJECTIDENTIFIER
::={ ciscoSyslogMIB 2}ciscoSyslogMIBNotifications OBJECTIDENTIFIER::={ ciscoSyslogMIBNotificationPrefix 0}clogMessageGenerated NOTIFICATION-TYPEOBJECTS{ clogHistFacility,
clogHistSeverity,
clogHistMsgName,
clogHistMsgText,
clogHistTimestamp
}STATUScurrentDESCRIPTION"When a syslog message is generated by the device a
clogMessageGenerated notification is sent. The
sending of these notifications can be enabled/disabled
via the clogNotificationsEnabled object."::={ ciscoSyslogMIBNotifications 1}-- conformance informationciscoSyslogMIBConformance OBJECTIDENTIFIER::={ ciscoSyslogMIB 3}ciscoSyslogMIBCompliances OBJECTIDENTIFIER::={ ciscoSyslogMIBConformance 1}ciscoSyslogMIBGroups OBJECTIDENTIFIER
::={ ciscoSyslogMIBConformance 2}-- compliance statementsciscoSyslogMIBCompliance MODULE-COMPLIANCESTATUSdeprecated-- superceded by ciscoSyslogMIBComplianceRev1DESCRIPTION"The compliance statement for entities which implement
the Cisco syslog MIB."MODULE-- this moduleMANDATORY-GROUPS{ ciscoSyslogMIBGroup }::={ ciscoSyslogMIBCompliances 1}ciscoSyslogMIBComplianceRev1 MODULE-COMPLIANCE
STATUScurrentDESCRIPTION"The compliance statement for entities which implement
the Cisco syslog MIB."MODULE-- this moduleMANDATORY-GROUPS{ ciscoSyslogMIBGroup }GROUP clogServerGroup
DESCRIPTION"The implementation of this group is
mandatory for those systems where
configuration of remote syslog server hosts
is supported."GROUP clogOriginIDGroup
DESCRIPTION"The implementation of this group is
mandatory for those systems where
syslog origin identifier is supported."
GROUP clogNotificationsGroup
DESCRIPTION"The implementation of this group is
mandatory for those systems where
syslog notification is supported."::={ ciscoSyslogMIBCompliances 2}-- units of conformanceciscoSyslogMIBGroup OBJECT-GROUPOBJECTS{ clogNotificationsSent,
clogNotificationsEnabled,
clogMaxSeverity,
clogMsgIgnores,
clogMsgDrops,
clogHistTableMaxLength,
clogHistMsgsFlushed,
clogHistFacility,
clogHistSeverity,
clogHistMsgName,
clogHistMsgText,
clogHistTimestamp
}STATUScurrentDESCRIPTION"A collection of objects providing the syslog
MIB capability."::={ ciscoSyslogMIBGroups 1}clogNotificationsGroup NOTIFICATION-GROUPNOTIFICATIONS{
clogMessageGenerated
}STATUScurrentDESCRIPTION
"A collection of notification(s) for syslog feature."::={ ciscoSyslogMIBGroups 2}clogServerGroup OBJECT-GROUPOBJECTS{
clogMaxServers,
clogServerStatus
}STATUScurrentDESCRIPTION"A collection of objects providing syslog server
information for the system."::={ ciscoSyslogMIBGroups 3}clogOriginIDGroup OBJECT-GROUPOBJECTS{
clogOriginIDType,
clogOriginID
}STATUScurrentDESCRIPTION"A collection of objects providing information
on origin of syslog messages."::={ ciscoSyslogMIBGroups 4}END